Request a quote or Get in touch +91 - 9899 63 88 43
 

 

Laminar Flow Bench Horizontal
Microrocessor Based LED + LCD Controller
Password protection, UV Tube & Front Door Interlocking, UV Tube life meter,
HEPA Filter life meter & alarm
  1. Cleanliness Level : Class 100 as per US Federal Standard 209 E  
2. Working Table : Made of perforated stainless steel sheet stain finished.
3. Front Door : Made of clear perpex sheet/ polycarbonate sheet
4. Standard Parts : HEPA Filter, Pre Filter, Blower Assembly, Ultra Violet Lamp, Illumination
5. Standard Accessories : Pressure manometer, Gas inlet nozzle, floor leveling screws & wire cord
6. Power Supply : 220 V 50 Hz, Single Phase, AC supply
 
 
Special Feature
• Password protection (Programmable) for authorised operation
• Initial self cleaning cycle with programmable time
• Real time Clock
• UV timer showing used time and balance available life in hours
• Total HEPA Filter timer showing used time and balance available life in hours
• HEPA filter alarm after HEPA filter life is over and guideline for further action through LCD controller
• UV light/Door/Fluorescent Light Inter Lock i.e. UV switches ON only when door is closed, and automatically
  switches OFF fluorescent lights.
• If UV light is ON & the operator tries to open the door, it raises audio visual alarm.
 
 
Construction Options
  (i) Body made of Mild Steel/G.I. Sheet duly powder coated (totally in white colour) with S.S. table top
 
S. NO. Metallic CRC
/GI body
with S.S 304
worktop
WORKING
TABLE (in mm)
SIZE OF
HEPA FILTER
No. of PRE-
FILTER
No. of
Motor
Illumi-
nation
Details of UV
Tube
(range 254 nm)

(a)

2

600x600x600
(2'x2'x2')

600x600x150
(2' x 2' x6”)

1

1

2 x 20 W

1 x 15 W

(b)

3

900x600x600
(3'x2'x2')

900x600x150
(3' x 2' x6”)

1

1

2 x 20 W

1 x 30 W

(c)

4

1200x600x600
(4'x2'x2')

1200x600x150
(4' x 2' x6”)

1

1

2 x 40 W

1 x 30 W

(d)

6

1800x600x600
(6' x 2' x 2')

900x600x150
(3' x 2' x6”)
(x 2 filters)

2

2

4 x 20 W

1 x 30 W

(e)

8

2400x600x600
(8' x 2' x 2')

1200x600x150
(4' x 2' x6”)
(x 2 filters)

2

2

4 x 40 W

2 x 30 W

   
  (ii) Full body made of S.S. 304. (G.M.P. Model)
S. NO. Stainless Steel
body with S.S 304
worktop
WORKING
TABLE (in mm)
SIZE OF
HEPA FILTER
No. of PRE-
FILTER
No. of
Motor
Illumi-
nation
Details of UV
Tube
(range 254 nm)

(a)

2

600x600x600
(2'x2'x2')

600x600x150
(2' x 2' x6”)

1

1

2 x 20 W

1 x 15 W

(b)

SSH-3

900x600x600
(3'x2'x2')

900x600x150
(3' x 2' x6”)

1

1

2 x 20 W

1 x 30 W

(c)

4

1200x600x600
(4'x2'x2')

1200x600x150
(4' x 2' x6”)

1

1

2 x 40 W

1 x 30 W

(d)

6

1800x600x600
(6' x 2' x 2')

900x600x150
(3' x 2' x6”)
(x 2 filters)

2

2

4 x 20 W

1 x 30 W

(e)

8

2400x600x600
(8' x 2' x 2')

1200x600x150
(4' x 2' x6”)
(x 2 filters)

2

2

4 x 40 W

2 x 30 W

  * Other sizes can be manufactured against requirement.  
   
 
  OPTIONAL   
(a) Motor Blower to be switched off as soon as the door is fully closed (Please Suffix 0 for cat no.)
(b) IQ/OQ/PQ/DQ certificates
(c) Onsite Particle Counting Test with Air velocity & other tests. Within Delhi
   
 